TOMEY Ultrasound A Scan AL-4000

TOMEY Ultrasound A Scan AL-4000 measures the distance between living tissue, utilizing ultrasound waves generated from the ultrasound transducer built into the measurement probe. This device is designed to measure the axial length and corneal thickness at optical clinics and allows you to identify areas with pathological changes by observing mode-A waveforms. Product NOT SOLD in the U.S.A.

 DOWNLOAD CATALOG       PRODUCT MANUAL

SKU: A Scan AL-4000 Categories: , Tags: , , , ,
Description

TOMEY Ultrasound A Scan AL-4000 is an extremely handy and easy-to-use combination of Bio and Pachymeter leaves nothing to wish for in terms for comfort and flexibility. A wireless plus , fully integrated IOL power calculation software.

Features

  • Post-refractive cases – quick and reliable
  • Perfect K values – best toric results
  • Hill-RBF-method- for excellent refraction outcome
  • Outstanding optic measurement results
  • Biometry of the entire eye in a single measurement
  • Frontiers in IOL Prediction
  • Open data and an intuitive user interface
  • Improved refractive outcomes
  • Access to full eye data in a single click
  • Hit the target any time
  • Excellent IOL prediction in all eyes
  • Fast, precise and comprehensive refractive results

Measurements

  • Axial length
  • Corneal thickness
  • Anterior chamber depth
  • Aqueous depth
  • Lens thickness
  • Corneal curvature
  • Radii for flat and steep meridian
  • Axis of the flat meridian
  • White-to-white distance
  • Pupil diameter

Software

  • Biometer
  • Keratometer
  • Pachymeter
  • Pupillometer
  • IOL calculator
  • T-Cone Toric Platform
  • Automated Positioning System APS
  • Premium post refractive calculation

Biometry / IOL power calculations

AXIAL LENGTH Measurement range 13.00 to 45.00mm
ANTERIOR CHAMBER DEPTH Measurement range Measurement range 1.50 to 7.00mm
LENS THICKNESS Measurement range 2.00 to 6.00mm
MEASUREMENT ACCURACY ±0.1mm
MEASUREMENT RESOLUTION 0.01mm
IOL POWER CALCULATION SRKII / SRK/T / HOLLADAY / Hoffer Q / HAIGIS Standard

Biometry Probe

TYPE Solid state
FIXLIGHT Built in the probe, Red LED
TRANSDUCER FREQUENCY 10MHz
TIP DIAMETER 6.0mmφ(concave
DIMENSION / WEIGHT 14.0mmφ×98mm/40g

Function of Pachymetry

MEASUREMENT RANGE 150 to 1,500μm
MEASUREMENT ACCURACY ±5μm
MEASUREMENT RESOLUTION 1μm
CONVERTED VELOCITY 1,640m/s / 1,400 to 2,000m/s

Pachymetry Probe

TYPE Solid state
FIXLIGHT Built in the probe, Red LED
TRANSDUCER FREQUENCY 20MHz
TIP DIAMETER 1.5mmφ with an angle of 45°(flat)
DIMENSION / WEIGHT 8.8mmφ×90mm/30g

A-scan Diagnosis

DISPLAY LINE ANALYSIS 64mm
DISPLAY POINT ANALYSIS 45mm
A SCAN TYPE Solid state
A SCAN TRANSDUCER FREQUENCY 0MHz
A SCAN TIP DIAMETER 5mmφ(flat)
A SCAN DIMENSIONS 8mmφ×97mm / 30g

Main Unit

TFT LCD 3.5 inch color
DIMENSION & WEIGHT 109(W)×52(D)×166(H) 470g
ADAPTER VOLTAGE 100-120/220-240 VAC
FREQUENCY 50 / 60Hz
POWER CONSUMPTION 18/24 VA
BUILT-IN BATTERY VOLTAGE DC 3.7V

BATTERY & ADAPTER

BATTERY Lithium ion battery
VOLTAGE DC 3.7V
MANUFACTURER SINPRO ELECTRONICS CO., LTD
MODEL 1UF603443S
POWER CONSUMPTION 18/24 VA

Video Demo

How to find us

Viewlight is a leading provider of medical practice equipment for ophthalmologists, optometrists and opticians.

Ask a question

    Additional information
    Brand

    TOMEY

    Country of Origin

    Made in Japan

    Optional Accessories

    Single Item Work Station

    Reviews (0)

    Reviews

    There are no reviews yet.

    Only logged in customers who have purchased this product may leave a review.

    About TOMEY
    Shipping and Receiving

    SHIPPING & DELIVERY

    Orders are shipped Monday through Friday, please contact your sell representative or customer service for exact information.

    If depend on many factors , due instruments needs to be inspected and tested before shipping,  please contact your sell representative or customer service for exact information.

    Contact customer service immediately. Sometimes Cancellations are no longer possible as your order will already have been sent to our fulfillment center. You will have to wait until the item is delivered and then return it for a full refund.

    Unfortunately, we cannot modify an order once it has been placed. We offer return policy if you'd like to return any unwanted products once they've been delivered, please contact customer service immediately.

    These policies only apply within the United States. If you are not in the United States, we don’t accept any returned or cancellation.

    All orders are processed within 3-7 business days. Orders are not shipped or delivered on weekends or holidays. If we are experiencing a high volume of orders, shipments may be delayed by a few days. Please allow additional days in transit for delivery. If there will be a significant delay in shipment of your order, we will contact you via email or telephone.

    Viewlight USA Full Shipping Policies: SEE ALL

    Shipping Services
    About Brand

    Viewlight USA is engaged in the development, sale, and maintenance for most of the ophthalmic and optical instruments. Viewlight USA is established and located in Miami, FL. We offer top of the line equipment with the latest medical technologies and a commitment to provide the finest medical equipment in the market.

    We are proud to partner up with leading optics brands: CSO | Inami & Co., Ltd | Haag-Streit.